biologically effective dose (BED)
In fractionated radiotherapy, the quantity by which different fractionation regimens are compared.
What is biologically effective dose (bed)?
The linear-quadratic model expresses the effect of n well-separated fractions of dose d as E = n(αd + βd²). Dividing by α gives BED = nd[1 + d/(α/β)], which permits comparison of fractionation schedules for a specified tissue response. The chosen α/β must be retained: the chapter explicitly warns that BED values calculated for early and late effects cannot meaningfully be compared with one another.